# Polish Power Pwnage: Wipers, Wind Farms, and Wake-Up Calls

- Link: https://www.agilicus.com/polish-power-pwnage-wipers-wind-farms-and-wake-up-calls/
- Published: 2026-01-30T20:53:49+00:00
- Author: Don Bowman

## The lights stayed on, but the SCADA systems are toast. Here is why your distributed energy assets are the next target.

It looks like the bad actors didn’t get the memo about taking time off for the holidays.
While you were likely arguing with relatives over turkey or trying to ignore work
emails, Poland’s power grid was fending off a coordinated assault. In late December,
a group known as Electrum (friends of the notorious Sandworm) decided to turn the
lights out — or at least, try to. They targeted Distributed Energy Resources (DER)
across the country, aiming to wipe operational technology (OT) off the map. The 
good news? The lights stayed on. The bad news? Approximately 30 facilities had their
systems bricked, damaging key equipment beyond repair. This wasn’t a failure on 
the attacker’s part; it was a warning shot. If you think your infrastructure is 
safe because you have a firewall and a prayer, you need to pay attention.

### Electrum’s Holiday Special: Bricking the Grid

Late December is the perfect time for **shenanigans**. While IT teams were operating
on skeleton crews and holiday leftovers, the threat group Electrum — closely linked
to the infamous Sandworm and their Greatest Hits album of malware like **Industroyer2**
and **Caddywiper** — launched a coordinated assault on Poland’s grid. According 
to [ESET Research](https://www.welivesecurity.com/en/eset-research/eset-research-sandworm-cyberattack-poland-power-grid-late-2025/),
this wasn’t a script kiddie poking around; it was a targeted campaign using wipers
to scrub the brains out of critical infrastructure.

The targets weren’t your grandfather’s massive coal plants. They went after the 
modern, fragmented edge: Distributed Energy Resources (DER). We are talking about
wind farms, solar dispatch systems, and Combined Heat and Power (CHP) facilities.
[BleepingComputer](https://www.bleepingcomputer.com/news/security/cyberattack-on-polish-energy-grid-impacted-around-30-facilities/)
notes that while official reports confirm 12 affected sites, researchers at Dragos
estimate the real count is closer to 30. That is a significant **blast radius**.

Here is the part that grinds my gears. The Polish government called the attack a“
failure” because the lights didn’t go out. [Reuters](https://www.reuters.com/sustainability/climate-energy/massive-cyberattack-polish-power-system-december-failed-minister-says-2026-01-13/)
reported that while 1.2 GW (about 5% of supply) was affected, the grid stayed stable.
But let’s be blunt: if a burglar smashes every window in your house and torches 
your furniture, but the roof doesn’t collapse, you don’t call that a “win.” The 
OT equipment was **bricked beyond repair**. The SCADA systems are dead. The hardware
has to be physically replaced. That is not a failed attack; that is a distinct, 
expensive, and terrifyingly successful proof of concept that proves our new, green
grid is made of plywood.

### The Distributed Disaster: Soft Targets in the Middle of Nowhere

We used to defend the grid like a bank vault: thick concrete, armed guards, and 
a centralised control room. But the energy transition has turned that architecture
inside out. Now, instead of one massive plant, we have thousands of wind turbines
and solar farms scattered across rural fields, usually miles from the nearest paved
road. It creates a massive, undefendable surface area where physical security consists
of a padlock and a prayer.

These Distributed Energy Resources (DERs) are often stuck on cellular connections
or Starlink because running fibre to a cornfield isn’t economically viable. This
leads to a networking dumpster fire involving Carrier-Grade NAT (CGNAT). Since standard
inbound connections don’t work through that mess, integrators create workarounds.
They install unmanaged ‘jump boxes’ running TeamViewer or VNC just to keep the lights
on without rolling a truck for every minor alert.

This is where the ‘Air Gap’ myth falls apart. As I’ve written in [The Distributed Dilemma](https://www.agilicus.com/the-distributed-dilemma-securing-renewable-energy-in-the-middle-of-nowhere/),
that gap isn’t empty space; it’s filled with third-party contractors and insecure
remote access tools. The perimeter isn’t just porous; it doesn’t exist.

In the Polish attack, the bad actors didn’t need to crack the encryption on a Programmable
Logic Controller (PLC) immediately. They just had to compromise the Windows edge
device sitting on that messy network. Once inside the ‘trusted’ zone, they moved
laterally with ease. The OT equipment, designed for a world where local traffic 
was always friendly, accepted the wipe commands without question. We have built 
a glass house, handed out rocks, and acted surprised when the windows shattered.

### Stop Trusting the Wire: A Blueprint for Survival

If you are still relying on a firewall to protect your OT, you are building a castle
on a swamp. The breach in Poland demonstrated that once the perimeter is pierced—
likely through a compromised Windows box — the bad actors can pivot to the operational
technology because the internal network is wide open. We need to stop trusting the
physical wire and start trusting cryptography and identity. As discussed in [Porous Perimeters and Pro-Russian Pwning](https://www.agilicus.com/porous-perimeters-and-pro-russian-pwning-the-la-poste-lesson/),
relying on “security by obscurity” or air gaps that don’t actually exist is a recipe
for disaster. Here is how you actually fix this mess:

 * **Kill the VPN:** I will say this until I am blue in the face: a VPN is just 
   a long Ethernet cable. It connects networks, not people. If an attacker compromises
   a contractor’s laptop, the VPN gives them a free ride past your drawbridge and
   direct access to the soft underbelly of your SCADA network. If they breach the
   perimeter, they own the network.
 * **Identity is the New Perimeter:** You must move to a Zero Trust architecture.
   We need to stop authenticating network packets and start authenticating the _user_.
   It does not matter if the request comes from inside the building or a coffee 
   shop; if the identity isn’t verified with strong multi-factor authentication (
   and no, SMS doesn’t count), they don’t get in.
 * **Segmentation:** A wind farm in Gdansk has absolutely no business talking to
   a control centre server in Warsaw without a visa check. Strict segmentation ensures
   that if a wiper takes out one site, the blast radius stops there.
 * **Identity-Aware Proxy:** This is the endgame. By using an outbound-only connection
   to a cloud broker, your infrastructure becomes invisible to scanners like Shodan.
   If they can’t scan it, they can’t pwn it.

## Conclusions

We got lucky with Poland. The attackers managed to destroy the brains of the operation—
the SCADA and OT systems — but failed to trip the breakers on a massive scale. Do
not mistake this luck for resilience. This incident proves that the distributed 
nature of modern energy grids creates a massive, porous attack surface that legacy
VPNs and firewalls simply cannot cover. The ‘Air Gap’ is a fairy tale we tell ourselves
to sleep better at night. It is time to stop trusting the network and start verifying
the human. Implement Zero Trust, use an Identity-Aware Proxy, and lock down your
access before your own systems get turned into expensive paperweights. Class dismissed.